Delete an Offline RAID6 virtual drive and create a new one with AVAGO storcli

Author:

Offline virtual device means it cannot be used because the missing or bad or failed disks are more than the fault tolerance it is offering. In this case, there is a RAID 6 on a AVAGO MegaRAID 3018 controller with 2 x RAID6 virtual drives with 6 disks each. One of the virtual drives misses 3 of the 6 disks in the group, so this virtual drive is in Offline state and it cannot be repaired. Three new disks are put to replace the failed disks. Here is what command to issue with the AVAGO command-line utility storcli under CentOS 7 to delete and then create a healthy new RAID 6 virtual drive:

  1. Delete the Offline virtual drive.
  2. Create a new RAID 6 virtual drive with 6 disks.
  3. Initialize the newly create virtual drive to make it consistent.

On each step, it is included additional show storcli commands to better preset what happens in reality and how the controller reflects the changes.
The initial state of the whole configuration is shown below:

[root@srv ~]# /opt/MegaRAID/storcli/storcli64 /c0 show
Generating detailed summary of the adapter, it may take a while to complete.

CLI Version = 007.0709.0000.0000 Aug 14, 2018
Operating system = Linux 3.10.0-957.1.3.el7.x86_64
Controller = 0
Status = Success
Description = None

Product Name = AVAGO 3108 MegaRAID
Serial Number = FW-AC5CMJEAARBWA
SAS Address =  500304802426b600
PCI Address = 00:01:00:00
System Time = 09/20/2022, 14:09:12
Mfg. Date = 00/00/00
Controller Time = 09/20/2022, 14:09:08
FW Package Build = 24.21.0-0028
BIOS Version = 6.36.00.2_4.19.08.00_0x06180202
FW Version = 4.680.00-8290
Driver Name = megaraid_sas
Driver Version = 07.705.02.00-rh1
Current Personality = RAID-Mode 
Vendor Id = 0x1000
Device Id = 0x5D
SubVendor Id = 0x15D9
SubDevice Id = 0x809
Host Interface = PCI-E
Device Interface = SAS-12G
Bus Number = 1
Device Number = 0
Function Number = 0
Drive Groups = 2

TOPOLOGY :
========

----------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type  State BT      Size PDC  PI SED DS3  FSpace TR 
----------------------------------------------------------------------------
 0 -   -   -        -   RAID6 OfLn  N  43.654 TB dflt N  N   dflt N      N  
 0 0   -   -        -   RAID6 Dgrd  N  43.654 TB dflt N  N   dflt N      N  
 0 0   0   -        -   DRIVE Msng  -  10.913 TB -    -  -   -    -      N  
 0 0   1   8:1      13  DRIVE Onln  N  10.913 TB dflt N  N   dflt -      N  
 0 0   2   8:2      10  DRIVE Onln  N  10.913 TB dflt N  N   dflt -      N  
 0 0   3   -        -   DRIVE Msng  -  10.913 TB -    -  -   -    -      N  
 0 0   4   8:4      11  DRIVE Onln  N  10.913 TB dflt N  N   dflt -      N  
 0 0   5   -        -   DRIVE Msng  -  10.913 TB -    -  -   -    -      N  
 1 -   -   -        -   RAID6 Optl  N  43.654 TB dflt N  N   dflt N      N  
 1 0   -   -        -   RAID6 Optl  N  43.654 TB dflt N  N   dflt N      N  
 1 0   0   8:6      20  DRIVE Onln  N  10.913 TB dflt N  N   dflt -      N  
 1 0   1   8:7      19  DRIVE Onln  N  12.732 TB dflt N  N   dflt -      N  
 1 0   2   8:8      18  DRIVE Onln  N  10.913 TB dflt N  N   dflt -      N  
 1 0   3   8:9      15  DRIVE Onln  N  10.913 TB dflt N  N   dflt -      N  
 1 0   4   8:10     12  DRIVE Onln  N  10.913 TB dflt N  N   dflt -      N  
 1 0   5   8:11     14  DRIVE Onln  N  10.913 TB dflt N  N   dflt -      N  
----------------------------------------------------------------------------

DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID
DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded
Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active
PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign
DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present
TR=Transport Ready

Virtual Drives = 2

VD LIST :
=======

------------------------------------------------------------------
DG/VD TYPE  State Access Consist Cache Cac sCC      Size Name     
------------------------------------------------------------------
0/0   RAID6 OfLn  RW     No      RAWBD -   ON  43.654 TB storage1 
1/1   RAID6 Optl  RW     Yes     RAWBD -   ON  43.654 TB storage2 
------------------------------------------------------------------

Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency

Physical Drives = 12

PD LIST :
=======

---------------------------------------------------------------------------------
EID:Slt DID State DG      Size Intf Med SED PI SeSz Model                Sp Type 
---------------------------------------------------------------------------------
8:0       9 UGood -  12.732 TB SATA HDD N   N  512B ST14000NM001G-2KJ103 D  -    
8:1      13 Onln  0  10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
8:2      10 Onln  0  10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
8:3      17 UGood -  12.732 TB SATA HDD N   N  512B ST14000NM001G-2KJ103 D  -    
8:4      11 Onln  0  10.913 TB SATA HDD N   N  512B ST12000NM001G-2MV103 U  -    
8:5      16 UGood -  12.732 TB SATA HDD N   N  512B ST14000NM001G-2KJ103 D  -    
8:6      20 Onln  1  10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
8:7      19 Onln  1  12.732 TB SATA HDD N   N  512B ST14000NM001G-2KJ103 U  -    
8:8      18 Onln  1  10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
8:9      15 Onln  1  10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
8:10     12 Onln  1  10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
8:11     14 Onln  1  10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
---------------------------------------------------------------------------------

EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down/PowerSave|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded


Cachevault_Info :
===============

------------------------------------
Model  State   Temp Mode MfgDate    
------------------------------------
CVPM02 Optimal 28C  -    2018/01/11 
------------------------------------

The show storcli command for the first virtual drive “/c0/v0” is also possible:

[root@srv ~]# /opt/MegaRAID/storcli/storcli64 /c0/v0 show all
CLI Version = 007.0709.0000.0000 Aug 14, 2018
Operating system = Linux 3.10.0-957.1.3.el7.x86_64
Controller = 0
Status = Success
Description = None


/c0/v0 :
======

------------------------------------------------------------------
DG/VD TYPE  State Access Consist Cache Cac sCC      Size Name     
------------------------------------------------------------------
0/0   RAID6 OfLn  RW     No      RAWBD -   ON  43.654 TB storage1 
------------------------------------------------------------------

Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency


PDs for VD 0 :
============

---------------------------------------------------------------------------------
EID:Slt DID State DG      Size Intf Med SED PI SeSz Model                Sp Type 
---------------------------------------------------------------------------------
8:1      13 Onln   0 10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
8:2      10 Onln   0 10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
8:4      11 Onln   0 10.913 TB SATA HDD N   N  512B ST12000NM001G-2MV103 U  -    
---------------------------------------------------------------------------------

EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down/PowerSave|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded


VD0 Properties :
==============
Strip Size = 1.0 MB
Number of Blocks = 93746888704
VD has Emulated PD = Yes
Span Depth = 1
Number of Drives Per Span = 6
Write Cache(initial setting) = WriteBack
Disk Cache Policy = Disk's Default
Encryption = None
Data Protection = Disabled
Active Operations = None
Exposed to OS = Yes
OS Drive Name = N/A
Creation Date = 19-12-2018
Creation Time = 06:11:08 AM
Emulation type = default
Cachebypass size = Cachebypass-64k
Cachebypass Mode = Cachebypass Intelligent
Is LD Ready for OS Requests = Yes
SCSI NAA Id = 600304802426b60023ac9d7c0a7a305b
SCSI Unmap = No

STEP 1) Delete the Offline virtual drive.

Delete the first virtual drive, which is “/c0/v0” using storcli:

[root@srv ~]# /opt/MegaRAID/storcli/storcli64 /c0/v0 del
CLI Version = 007.0709.0000.0000 Aug 14, 2018
Operating system = Linux 3.10.0-957.1.3.el7.x86_64
Controller = 0
Status = Success
Description = Delete VD succeeded

Because the virtual drive has been already in Offline state and the data on it is lost, there is no confirmation when deleting such device. So be careful when executing DELETE command on a such virtual drive.
And the result may be shown with the storcli show:

[root@srv ~]# /opt/MegaRAID/storcli/storcli64 /c0 show
Generating detailed summary of the adapter, it may take a while to complete.

CLI Version = 007.0709.0000.0000 Aug 14, 2018
Operating system = Linux 3.10.0-957.1.3.el7.x86_64
Controller = 0
Status = Success
Description = None

Product Name = AVAGO 3108 MegaRAID
Serial Number = FW-AC5CMJEAARBWA
SAS Address =  500304802426b600
PCI Address = 00:01:00:00
System Time = 09/20/2022 18:17:16
Mfg. Date = 00/00/00
Controller Time = 09/20/2022 18:15:28
FW Package Build = 24.21.0-0028
BIOS Version = 6.36.00.2_4.19.08.00_0x06180202
FW Version = 4.680.00-8290
Driver Name = megaraid_sas
Driver Version = 07.705.02.00-rh1
Current Personality = RAID-Mode 
Vendor Id = 0x1000
Device Id = 0x5D
SubVendor Id = 0x15D9
SubDevice Id = 0x809
Host Interface = PCI-E
Device Interface = SAS-12G
Bus Number = 1
Device Number = 0
Function Number = 0
Drive Groups = 1

TOPOLOGY :
========

----------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type  State BT      Size PDC  PI SED DS3  FSpace TR 
----------------------------------------------------------------------------
 0 -   -   -        -   RAID6 Optl  N  43.654 TB dflt N  N   dflt N      N  
 0 0   -   -        -   RAID6 Optl  N  43.654 TB dflt N  N   dflt N      N  
 0 0   0   8:6      20  DRIVE Onln  N  10.913 TB dflt N  N   dflt -      N  
 0 0   1   8:7      19  DRIVE Onln  N  12.732 TB dflt N  N   dflt -      N  
 0 0   2   8:8      18  DRIVE Onln  N  10.913 TB dflt N  N   dflt -      N  
 0 0   3   8:9      15  DRIVE Onln  N  10.913 TB dflt N  N   dflt -      N  
 0 0   4   8:10     12  DRIVE Onln  N  10.913 TB dflt N  N   dflt -      N  
 0 0   5   8:11     14  DRIVE Onln  N  10.913 TB dflt N  N   dflt -      N  
----------------------------------------------------------------------------

DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID
DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded
Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active
PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign
DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present
TR=Transport Ready

Virtual Drives = 1

VD LIST :
=======

------------------------------------------------------------------
DG/VD TYPE  State Access Consist Cache Cac sCC      Size Name     
------------------------------------------------------------------
0/1   RAID6 Optl  RW     Yes     RAWBD -   ON  43.654 TB storage2 
------------------------------------------------------------------

Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency

Physical Drives = 12

PD LIST :
=======

---------------------------------------------------------------------------------
EID:Slt DID State DG      Size Intf Med SED PI SeSz Model                Sp Type 
---------------------------------------------------------------------------------
8:0       9 UGood -  12.732 TB SATA HDD N   N  512B ST14000NM001G-2KJ103 D  -    
8:1      13 UGood -  10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
8:2      10 UGood -  10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
8:3      17 UGood -  12.732 TB SATA HDD N   N  512B ST14000NM001G-2KJ103 D  -    
8:4      11 UGood -  10.913 TB SATA HDD N   N  512B ST12000NM001G-2MV103 U  -    
8:5      16 UGood -  12.732 TB SATA HDD N   N  512B ST14000NM001G-2KJ103 D  -    
8:6      20 Onln  0  10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
8:7      19 Onln  0  12.732 TB SATA HDD N   N  512B ST14000NM001G-2KJ103 U  -    
8:8      18 Onln  0  10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
8:9      15 Onln  0  10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
8:10     12 Onln  0  10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
8:11     14 Onln  0  10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
---------------------------------------------------------------------------------

EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down/PowerSave|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded


Cachevault_Info :
===============

------------------------------------
Model  State   Temp Mode MfgDate    
------------------------------------
CVPM02 Optimal 28C  -    2018/01/11 
------------------------------------

Now, there are 6 hard drives in UGood state, which means they are ready to be used in a new RAID setup.

STEP 2) Create a new RAID 6 virtual drive with 6 disks.

Create the RAID 6 virtual drive with 6 hard drives, enabled Write-Back (i.e. caching writes) and Stripe Size 1024Kbytes, which is 1Mbyte.

[root@srv ~]# /opt/MegaRAID/storcli/storcli64 /c0 add vd r6 Size=all name=storage1 drives=8:0-1,2,3,4,5 WB Strip=1024
CLI Version = 007.0709.0000.0000 Aug 14, 2018
Operating system = Linux 3.10.0-957.1.3.el7.x86_64
Controller = 0
Status = Success
Description = Add VD Succeeded

Enumerating the disks is in this format Enclosure_Number:disk_1,disk_2….disk_N
The create command succeeded and the new virtual drive is again with number 0, so /c0/v0:

[root@srv ~]# /opt/MegaRAID/storcli/storcli64 /c0/v0 show all
CLI Version = 007.0709.0000.0000 Aug 14, 2018
Operating system = Linux 3.10.0-957.1.3.el7.x86_64
Controller = 0
Status = Success
Description = None


/c0/v0 :
======

------------------------------------------------------------------
DG/VD TYPE  State Access Consist Cache Cac sCC      Size Name     
------------------------------------------------------------------
1/0   RAID6 Optl  RW     No      RWBD  -   ON  43.654 TB storage1 
------------------------------------------------------------------

Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency


PDs for VD 0 :
============

---------------------------------------------------------------------------------
EID:Slt DID State DG      Size Intf Med SED PI SeSz Model                Sp Type 
---------------------------------------------------------------------------------
8:0       9 Onln   1 12.732 TB SATA HDD N   N  512B ST14000NM001G-2KJ103 T  -    
8:1      13 Onln   1 10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
8:2      10 Onln   1 10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
8:3      17 Onln   1 12.732 TB SATA HDD N   N  512B ST14000NM001G-2KJ103 T  -    
8:4      11 Onln   1 10.913 TB SATA HDD N   N  512B ST12000NM001G-2MV103 U  -    
8:5      16 Onln   1 12.732 TB SATA HDD N   N  512B ST14000NM001G-2KJ103 T  -    
---------------------------------------------------------------------------------

EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down/PowerSave|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded


VD0 Properties :
==============
Strip Size = 1.0 MB
Number of Blocks = 93746888704
VD has Emulated PD = Yes
Span Depth = 1
Number of Drives Per Span = 6
Write Cache(initial setting) = WriteBack
Disk Cache Policy = Disk's Default
Encryption = None
Data Protection = Disabled
Active Operations = None
Exposed to OS = Yes
OS Drive Name = /dev/sda
Creation Date = 20-09-2022
Creation Time = 06:20:20 PM
Emulation type = default
Cachebypass size = Cachebypass-64k
Cachebypass Mode = Cachebypass Intelligent
Is LD Ready for OS Requests = Yes
SCSI NAA Id = 600304802426b6002abcc0e4bd1fce89
SCSI Unmap = No

The problem here is that the virtual drive is not initialized, which should be done on every new virtual drive! A background initialization may occur if the controller is set so, but it is better to start manually a foreground initialization.
If disks are from different enclosures – storcli with multiple disks from different enclosures.

STEP 3) Initialize the newly create virtual drive to make it consistent.

The virtual drive has been created, but as shown in the previous “storcli show” command it is not consistent. To be consistent and the controller to be sure of the healthy status of the virtual drive and its disks an initialization is needed. There two types of initialization – a background initialization (bgi in terms of storcli), which constructs a parity data from the current data on the disks and save them on them. And a (foreground) initialization, which means the controller will save zeros to all the disks.
Start foreground initialization with:

[root@srv ~]# /opt/MegaRAID/storcli/storcli64 /c0/v0 start init full
CLI Version = 007.0709.0000.0000 Aug 14, 2018
Operating system = Linux 3.10.0-957.1.3.el7.x86_64
Controller = 0
Status = Success
Description = Start INIT Operation Success

The progress can be viewed with:

[root@srv ~]# /opt/MegaRAID/storcli/storcli64 /c0/v0 show init
CLI Version = 007.0709.0000.0000 Aug 14, 2018
Operating system = Linux 3.10.0-957.1.3.el7.x86_64
Controller = 0
Status = Success
Description = None


VD Operation Status :
===================

-------------------------------------------------------
VD Operation Progress% Status      Estimated Time Left 
-------------------------------------------------------
 0 INIT              0 In progress 0 Seconds           
-------------------------------------------------------

[root@srv ~]# /opt/MegaRAID/storcli/storcli64 /c0/v0 show init
CLI Version = 007.0709.0000.0000 Aug 14, 2018
Operating system = Linux 3.10.0-957.1.3.el7.x86_64
Controller = 0
Status = Success
Description = None


VD Operation Status :
===================

-------------------------------------------------------
VD Operation Progress% Status      Estimated Time Left 
-------------------------------------------------------
 0 INIT              1 In progress 12 Hours 37 Minutes 
-------------------------------------------------------
[root@srv ~]# /opt/MegaRAID/storcli/storcli64 /c0/v0 show init
CLI Version = 007.0709.0000.0000 Aug 14, 2018
Operating system = Linux 3.10.0-957.1.3.el7.x86_64
Controller = 0
Status = Success
Description = None


VD Operation Status :
===================

-------------------------------------------------------
VD Operation Progress% Status      Estimated Time Left 
-------------------------------------------------------
 0 INIT             99 In progress 26 Minutes          
-------------------------------------------------------
[root@srv ~]# /opt/MegaRAID/storcli/storcli64 /c0/v0 show init
CLI Version = 007.0709.0000.0000 Aug 14, 2018
Operating system = Linux 3.10.0-957.1.3.el7.x86_64
Controller = 0
Status = Success
Description = None


VD Operation Status :
===================

-----------------------------------------------------------
VD Operation Progress% Status          Estimated Time Left 
-----------------------------------------------------------
 0 INIT      -         Not in progress -                   
-----------------------------------------------------------

And the configuration and the status of the virtual drives are as follows:

[root@srv ~]# /opt/MegaRAID/storcli/storcli64 /c0 show 
Generating detailed summary of the adapter, it may take a while to complete.

CLI Version = 007.0709.0000.0000 Aug 14, 2018
Operating system = Linux 3.10.0-957.1.3.el7.x86_64
Controller = 0
Status = Success
Description = None

Product Name = AVAGO 3108 MegaRAID
Serial Number = FW-AC5CMJEAARBWA
SAS Address =  500304802426b600
PCI Address = 00:01:00:00
System Time = 09/21/2022 13:26:11
Mfg. Date = 00/00/00
Controller Time = 09/21/2022 13:24:22
FW Package Build = 24.21.0-0028
BIOS Version = 6.36.00.2_4.19.08.00_0x06180202
FW Version = 4.680.00-8290
Driver Name = megaraid_sas
Driver Version = 07.705.02.00-rh1
Current Personality = RAID-Mode 
Vendor Id = 0x1000
Device Id = 0x5D
SubVendor Id = 0x15D9
SubDevice Id = 0x809
Host Interface = PCI-E
Device Interface = SAS-12G
Bus Number = 1
Device Number = 0
Function Number = 0
Drive Groups = 2

TOPOLOGY :
========

----------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type  State BT      Size PDC  PI SED DS3  FSpace TR 
----------------------------------------------------------------------------
 0 -   -   -        -   RAID6 Optl  N  43.654 TB dflt N  N   dflt N      N  
 0 0   -   -        -   RAID6 Optl  N  43.654 TB dflt N  N   dflt N      N  
 0 0   0   8:6      20  DRIVE Onln  N  10.913 TB dflt N  N   dflt -      N  
 0 0   1   8:7      19  DRIVE Onln  N  12.732 TB dflt N  N   dflt -      N  
 0 0   2   8:8      18  DRIVE Onln  N  10.913 TB dflt N  N   dflt -      N  
 0 0   3   8:9      15  DRIVE Onln  N  10.913 TB dflt N  N   dflt -      N  
 0 0   4   8:10     12  DRIVE Onln  N  10.913 TB dflt N  N   dflt -      N  
 0 0   5   8:11     14  DRIVE Onln  N  10.913 TB dflt N  N   dflt -      N  
 1 -   -   -        -   RAID6 Optl  N  43.654 TB dflt N  N   dflt N      N  
 1 0   -   -        -   RAID6 Optl  N  43.654 TB dflt N  N   dflt N      N  
 1 0   0   8:0      9   DRIVE Onln  N  12.732 TB dflt N  N   dflt -      N  
 1 0   1   8:1      13  DRIVE Onln  N  10.913 TB dflt N  N   dflt -      N  
 1 0   2   8:2      10  DRIVE Onln  N  10.913 TB dflt N  N   dflt -      N  
 1 0   3   8:3      17  DRIVE Onln  N  12.732 TB dflt N  N   dflt -      N  
 1 0   4   8:4      11  DRIVE Onln  N  10.913 TB dflt N  N   dflt -      N  
 1 0   5   8:5      16  DRIVE Onln  N  12.732 TB dflt N  N   dflt -      N  
----------------------------------------------------------------------------

DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID
DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded
Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active
PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign
DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present
TR=Transport Ready

Virtual Drives = 2

VD LIST :
=======

------------------------------------------------------------------
DG/VD TYPE  State Access Consist Cache Cac sCC      Size Name     
------------------------------------------------------------------
0/1   RAID6 Optl  RW     Yes     RAWBD -   ON  43.654 TB storage2 
1/0   RAID6 Optl  RW     Yes     RWBD  -   ON  43.654 TB storage1 
------------------------------------------------------------------

Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency

Physical Drives = 12

PD LIST :
=======

---------------------------------------------------------------------------------
EID:Slt DID State DG      Size Intf Med SED PI SeSz Model                Sp Type 
---------------------------------------------------------------------------------
8:0       9 Onln   1 12.732 TB SATA HDD N   N  512B ST14000NM001G-2KJ103 U  -    
8:1      13 Onln   1 10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
8:2      10 Onln   1 10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
8:3      17 Onln   1 12.732 TB SATA HDD N   N  512B ST14000NM001G-2KJ103 U  -    
8:4      11 Onln   1 10.913 TB SATA HDD N   N  512B ST12000NM001G-2MV103 U  -    
8:5      16 Onln   1 12.732 TB SATA HDD N   N  512B ST14000NM001G-2KJ103 U  -    
8:6      20 Onln   0 10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
8:7      19 Onln   0 12.732 TB SATA HDD N   N  512B ST14000NM001G-2KJ103 U  -    
8:8      18 Onln   0 10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
8:9      15 Onln   0 10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
8:10     12 Onln   0 10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
8:11     14 Onln   0 10.913 TB SATA HDD N   N  512B ST12000NM0007-2A1101 U  -    
---------------------------------------------------------------------------------

EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down/PowerSave|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded


Cachevault_Info :
===============

------------------------------------
Model  State   Temp Mode MfgDate    
------------------------------------
CVPM02 Optimal 28C  -    2018/01/11 
------------------------------------

The new virtual drive is reported as consistent, so it is healhty.

Leave a Reply

Your email address will not be published. Required fields are marked *